Others / Optical Barriers

Optical Barrier System


Introduction & Application

Operation of heavy duty press, cutters and similar machines involves safety hazards for human beings. Optical Safety Barriers, designed by JAYASHREE, is ideal for preventing accidents by sensing presence of any object in the Danger-Zone. This noise immune system has a very fast response to take care of high speed applications.


Applications

Human safety while working on heavy machines like press, bending machines Cutters,Machining Centres. Sensing on conveyor belts at Airports/ Passenger lifts. An advanced version incorporating movement sensors is also available


Operating Principle

The Barrier columns are mounted at entry positions of the danger zone. The controller unit can be mounted in the control panel of the machine. The transmitter unit continuously transmits infra-red light in a specific sequence from the no. of transmitter modules used. An individual beam is a high frequency modulated beam. A synchronization signal is sent to receiver unit for proper correlation. In the receiver, the individual sensors receive the signal from corresponding transmitter. This avoids cross-talk problem. If any of the beam is disrupted, the receiver immediately sends a signal to the controller unit to operate the output relay.


Standard Specifications

Supply Voltage : 110 / 240 V AC / DC

No. of Beams : 4 / 7 / 11 / 16 / 20 (User Defined)

Scanning Height : Depends upon No. of beams & Pitch

Sensing Range : 3.5 m

Enclosure : MS Fabricated


Available Models

MODEL NO. OF BEAMS SCANNING HEIGHT PITCH SENSING GAP
     

(c/c distance between two beams)

 
OBS 6057-3
3
60 / 100 mm 30 / 50 mm  
OBS 6075-4
4
90 / 150 mm 30 / 50 mm  
OBS 6057-6
6
150 / 250 mm 30 / 50 mm  
OBS 6057-7
7
180 / 300 mm 30 / 50 mm  
OBS 6057-8
8
210 / 350 mm 30 / 50 mm  
OBS 6057-11
11
300 / 500 mm 30 / 50 mm  
OBS 6057-16
16
450 / 750 mm 30 / 50 mm  
OBS 6057-20
20
570 / 950 mm 30 / 50 mm  
         

Mounting Arrangements

View-A : Normal mounting position with transmitter-receiver modules facing each other.
View-B : Transmitter/ Receiver modules are positioned this way in the column.
View-C : Normal mounting position asseen from the top
View-D : Top view of mounting position with transmitter mis-aligned
View-E : Top view of mounting position with receiver mis-aligned.
Views-D: and E are indicative of wrongmounting.
   

Phone: 91-020-27130295 / 30681343
Fax: 020-30681357

Jayashree Electrodevices Pvt Ltd
Phone: 91-020-30681323
Website - http://www.jayashree-electrodevices.org
E-mail: sales@jayashree-electrodevices.org

Jayashree Encoder Pvt Ltd.
Phone: 91-020-66308092
Website - http://www.jencoder.com
E-mail: sales@jencoder.com

Technology Partner- Fairford Electronics Ltd. UK
Website - http://www.fairford.co.uk
E-mail: sales@fairford.co.uk

ISO 9001—2008


Click here to view the Certificate